Services
Home batteriesSolar + battery systemsSolar panelsAdd a battery to solarEV chargersMain panel upgradesAll services →
Areas we serve
San FranciscoSan FranciscoNorth BayEast BayPeninsulaSouth BaySee every city →
Resources
Batteries · Sizing

How big a battery does a Bay Area home need?

Size from your 4 to 9pm load, not a rule of thumb.

SolarUnion Editorial TeamIndependent solar and battery guides
Updated 7 min read
In this article
The short answer
  • For bill savings, size storage to your typical 4 to 9pm use. Many Bay Area homes land between 10 and 15 kWh, which is one large battery or two to three modules.
  • For outage backup, size for the circuits you want running and for how long. Essentials need far less than whole-home backup.
  • Check power (kW) as well as energy (kWh). A heat pump or well pump can need more power than one small battery delivers.

Battery sizing goes wrong in two directions. Too small and the battery runs out at 7pm, leaving you buying peak power anyway. Too big and you pay for capacity your solar can never fill. The right size comes from three inputs: your evening use, your outage plan, and the largest loads you want to run at once.

Start with the goal

  • Bill savings. Under NEM 3.0 the battery's daily job is to cover the 4 to 9pm peak with stored solar.
  • Backup. During a PSPS shutoff or storm, keep chosen circuits running for a set number of hours, with solar refilling by day.
  • Both. Most Bay Area homeowners want both, and a design should state how it handles each.

Size the energy (kWh)

Pull a few months of hourly data from your PG&E account and add up use between 4 and 9pm on typical days. Take a value a little above the average, not the peak day. That is your daily storage target for bill savings. Then check your solar: the array has to produce enough surplus at midday to refill that much storage on most days, or the extra capacity sits idle.

For backup, list the loads you want on and estimate their average draw, then multiply by the hours you want covered. A fridge, lights, internet and a few outlets average well under 1 kW; adding electric heat, cooking or laundry changes the picture quickly.

Size the power (kW)

Energy is how long. Power is how much at once. Each battery has a continuous power rating and a short-burst rating for starting motors. A heat pump, well pump or AC compressor can draw several kilowatts on startup. If the battery cannot deliver it, the load will not start during an outage, no matter how full the battery is.

Worked examples

Home4 to 9pm useBackup goalTypical starting point
SF flat, gas heat and cooking5 to 7 kWhEssentialsAbout 10 kWh
East Bay bungalow, gas heat, one EV charged overnight8 to 12 kWhEssentials plus home officeAbout 13 to 15 kWh
Peninsula all-electric home with heat pump14 to 20 kWhWhole home including heat pumpAbout 27 to 30 kWh, high power rating
Hillside home on a well, high PSPS exposure10 to 14 kWhMulti-day essentials plus well pumpAbout 20 to 27 kWh, check pump surge
Illustrative starting points only. A real design uses your interval data, roof production and equipment specs.

Skip the guesswork.

A free estimate sizes energy and power from your PG&E history and outage plan.

Size my battery

Common sizing mistakes

  • Sizing to the annual bill instead of the evening load. A battery does not care about your yearly total.
  • Ignoring the solar side. A big battery on a small array cannot refill in winter.
  • Whole-home backup by default. Backing up the dryer and oven can double the battery cost for loads you can skip during an outage.
  • Forgetting power ratings. Capacity looks fine on paper while the heat pump will not start.
  • Not planning for change. An EV or heat pump on the horizon shifts evening use; modular systems or expansion units help.

Get a battery sized to your evenings.

From your real use, not a brochure.

Get my estimate
GuidesGet my estimate